Crystallization of Zika virus NS2B-NS3 protease
Peter Marples, Lizbé Koekemoer, Daren Fearon, xiaomin.ni Ni
crystallisation
XChem
ASAP
AViDD
CMD
Diamond Light Source
i04-1
Research complex at Harwell
Zika NS2BNS3
NS2BNS3
8PN6
Disclaimer
The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Acknowledgements:
Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot OX11 0QX, UK
Research Complex at Harwell, Harwell Science and Innovation Campus, Didcot OX11 0FA, UK
Oxford Lab Technologies crystal shifter https://doi.org/10.1107/S2059798320014114
Abstract
Zika virus (ZIKV) infections causes microcephaly in new-borns and Guillain-Barre syndrome in adults raising a global public health concern, yet no vaccines or antiviral drugs are available to treat or prevent ZIKV infections. The viral NS3 protease with its NS2B cofactor is essential for the cleavage of Zika polyprotein precursor into individual structural and non-structural proteins and is therefore an attractive drug target. We optimized a robust crystal system of co-expressed NS3 protease with its NS2B cofactor and used this in a crystallographic fragment screening campaign.
Steps
Equipment needed
Formulatrix Rock Imager (or incubator of choice)
Equipment
Value | Label |
---|---|
Mosquito HV | NAME |
High Volume 16-Channel Robotic Liquid Handler | TYPE |
SPT LabTech | BRAND |
3097-01057 | SKU |
P100 8 multi-channel pipette
Crystallization experiment
Protein and buffer requirements:
43.2µL``15mg/mL``Sample
2.88mL
Crystallisation screen composition:
30% w/v PEG 2000
0.2Molarity (M)
Ammonium sulfate
0.1Molarity (M)
sodium acetate 4.8
Stock solutions used:
1Molarity (M)
Ammonium sulfate
1Molarity (M)
Sodium acetate 4.8
50% w/v PEG 2000
Dispense 30µL
into SwissCI 3 lens plate reservoir wells using a 100 µl multi-channel pipette.
Dispense 150nL``15mg/mL``Sample
to each lens using the SPT mosquito.
Dispense 150nL
to each lens using the SPT mosquito.
Drop ratio: 1:1
Final drop volume: 300 nl
Incubate at 20°C
for 24h 0m 0s
in Formulatrix Rock Imager.
Imaging Schedule : The first images are taken after 12 h and the imaging schedule follows a Fibonacci sequence of days for further collections.

Data collection at Synchrotron
Diamond Light Source
Unattended Data Collection (UDC)
Data Collection Temperature: 100K
Detector: DECTRIS EIGER2 X 9M
Beamline: I04-1
Wavelength: 0.9212 Å
Resolution (Å): 1.62
Beam Size (μm): 60 X 50
Number of images: 3600
Oscillation: 0.10°
Exposure (s): 0.0020
Transmission (%): 100
Flux (ph/s): 9.50e+11